Twelve-crystal prototype of Li2MoO4 scintillating bolometers for CUPID and CROSS experiments
Autor:
Alfonso, K.
; Armatol, A.
; Augier, C.
; Avignone III, F. T.
; Azzolini, O.
; Balata, M.
; Bandac, I.C.
; Barabash, A. S.
; Bari, G.
; Barresi, A.
; Baudin, D.
; Bellini, F.
; Benato, G.
; Berest, V.
; Beretta, M.
; Bettelli, M.
; Biassoni, M.
; Billard, J.
; Boldrini, V.
; Branca, A.
; Brofferio, C.
; Bucci, C.
; Calvo-Mozota, José María
; Camilleri, J.
; Campani, A.
; Capelli, C.
; Capelli, S.
; Cappelli, L.
; Cardani, L.
; Carniti, P.
; Casali, N.
; Celi, E.
; Chang, C.
; Chiesa, D.
; Clemenza, M.
; Colantoni, I.
; Copello, S.
; Craft, E.
; Cremonesi, O.
; Creswick, R. J.
; Cruciani, A.
; D'Addabbo, A.
; D'Imperio, G.
; Dabagov, S.
; Dafinei, I.
; Danevich, F. A.
; De Jesus, M.
; de Marcillac, P.
; Dell'Oro, S.
; Di Domizio, S.
; Di Lorenzo, S.
; Dixon, T.
; Dompé, V.
; Drobizhev, A.
; Dumoulin, L.
; Fantini, G.
; Faverzani, M.
; Ferri, E.
; Ferri, F.
; Ferroni, F.
; Figueroa-Feliciano, E.
; Foggetta, L.
; Formaggio, J.
; Franceschi, A.
; Fu, C.
; Fu, S.
; Fujikawa, B. K.
; Gallas, A.
; Gascon, J.
; Ghislandi, S.
; Giachero, A.
; Gianvecchio, A.
; Girola, M.
; Gironi, L.
; Giuliani, A.
; Gorla, P.
; Gotti, C.
; Grant, C.
; Gras, P.
; Guillaumon, P. V.
; Gutierrez, T. D.
; Han, K.
; Hansen, E. V.
; Heeger, K. M.
; Helis, D. L.
; Huang, H. Z.
; Ianni, A.
; Imbert, L.
; Johnston, J.
; Juillard, A.
; Karapetrov, G.
; Keppel, G.
; Khalife, H.
; Kobychev, V. V.
; Kolomensky, Yu. G.
; Konovalov, S.I.
; Kowalski, R.
; Langford, T.
; Lefevre, M.
; Liu, R.
; Liu, Y.
; Loaiza, P.
; Ma, L.
; Madhukuttan, M.
; Mancarella, F.
; Marrache-Kikuchi, C. A.
; Marini, L.
; Marnieros, S.
; Martinez, M.
; Maruyama, R. H.
; Ph. Mas
; Mayer, D.
; Mazzitelli, G.
; Mei, Y.
; Milana, S.
; Morganti, S.
; Napolitano, T.
; Nastasi, M.
; Nikkel, J.
; Nisi, S.
; Nones, C.
; Norman, E. B.
; Novosad, V.
; Nutini, I.
; O'Donnell, T.
; Olivieri, E.
; Olmi, M.
; Ouellet, J. L.
; Pagan, S.
; Pagliarone, C.
; Pagnanini, L.
; Pattavina, L.
; Pavan, M.
; Peng, H.
; Pessina, G.
; Pettinacci, V.
; Pira, C.
; Pirro, S.
; Poda, D. V.
; Polischuk, O. G.
; Ponce, I.
; Pozzi, S.
; Previtali, E.
; Puiu, A.
; Quitadamo, S.
; Ressa, A.
; Rizzoli, R.
; Rosenfeld, C.
; Rosier, P.
; Scarpaci, J. A.
; Schmidt, B.
; Sharma, V.
; Shlegel, V. N.
; Singh, V.
; Sisti, M.
; Slocum, P.
; Speller, D.
; Surukuchi, P. T.
; Taffarello, L.
; Tomei, C.
; Torres, J. A.
; Tretyak, V. I.
; Tsymbaliuk, A.
; Velazquez, M.
; Vetter, K. J.
; Wagaarachchi, S. L.
; Wang, G.
; Wang, L.
; Wang, R.
; Welliver, B.
; Wilson, J.
; Wilson, K.
; Winslow, L. A.
; Xue, M.
; Yan, L.
; Yang, J
; Yefremenko, V.
; Umatov, V. I.
; Zarytskyy, M. M.
; Zhang, J.
; Zolotarova, A.
; Zucchelli, S.
Fecha:
2023Palabra clave:
Revista / editorial:
Journal of InstrumentationCitación:
Alfonso, K., Armatol, A., Augier, C., Avignone, F. T., Azzolini, O., Balata, M., ... & Scarpaci, J. A. (2023). Twelve-crystal prototype of Li_2MoO_4 scintillating bolometers for CUPID and CROSS experiments. Journal of Instrumentation, 18(06), P06018.Tipo de Ítem:
articleResumen:
An array of twelve 0.28 kg lithium molybdate (LMO) low-temperature bolometers equipped with 16 bolometric Ge light detectors, aiming at optimization of detector structure for CROSS and CUPID double-beta decay experiments, was constructed and tested in a low-background pulse-tube-based cryostat at the Canfranc underground laboratory in Spain. Performance of the scintillating bolometers was studied depending on the size of phonon NTD-Ge sensors glued to both LMO and Ge absorbers, shape of the Ge light detectors (circular vs. square, from two suppliers), in different light collection conditions (with and without reflector, with aluminum coated LMO crystal surface). The scintillating bolometer array was operated over 8 months in the low-background conditions that allowed to probe a very low, μBq/kg, level of the LMO crystals radioactive contamination by 228Th and 226Ra.
Ficheros en el ítem
Nombre: Twelve-crystal prototype of Li2MoO4 scintillating bolometers for CUPID and CROSS experiments.pdf
Tamaño: 7.302Mb
Formato: application/pdf
Este ítem aparece en la(s) siguiente(s) colección(es)
Estadísticas de uso
Año |
2012 |
2013 |
2014 |
2015 |
2016 |
2017 |
2018 |
2019 |
2020 |
2021 |
2022 |
2023 |
2024 |
Vistas |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
89 |
Descargas |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
18 |
Ítems relacionados
Mostrando ítems relacionados por Título, autor o materia.
-
Enhanced light signal for the suppression of pile-up events in Mo-based bolometers for the 0 νββ decay search.
Ahmine, A.; Armatol, A.; Bandac, Iulian Catalin; Bergé, L.; Calvo-Mozota, Jose Maria; Carniti, P.; Chapellier, M.; Dixon, T.; Dumoulin, L.; Giuliani, A.; Gras, Ph.; Ferri, F.; Imbert, L.; Khalife, H.; Loaiza, P.; de Marcillac, P.; Marnieros, S.; Marrache-Kikuchi, C.A.; Nones, C.; Olivieri, E.; de Solórzano, A. Ortiz; Pessina, G.; Poda, D.V.; Redon, Th.; Scarpaci, J.A.; Velázquez, M.; Zolotarova, A. (European Physical Journal C, 2023)Random coincidences of events could be one of the main sources of background in the search for neutrino-less double-beta decay of 100 Mo with macro-bolometers, due to their modest time resolution. Scintillating bolometers ... -
Test of 116CdWO4 and Li2MoO4 scintillating bolometers in the CROSS underground facility with upgraded detector suspension
Ahmine, A.; Bandac, I. C.; Barabash, A. S.; Berest, V.; Bergé, L.; Calvo-Mozota, José María; Carniti, P.; Chapellier, M.; Dafinei, I.; Danevich, F. A.; Dixon, T.; Dumoulin, L.; Ferri, F.; Giuliani, A.; Gott, C.; Gras, P.; Helis, D. L.; Ianni, A.; Imbert, L.; Khalife, H.; Kobychev, V. V.; Konovalov, S. I.; Loaiza, P.; de Marcillac, P.; Marnieros, S.; Marrache-Kikuchi, C. A.; Martinez, M.; Nones, C.; Olivieri, E.; Ortiz de Solórzano, A.; Peinaud, Y.; Pessina, G.; Poda, D. V.; Redon, Th.; Rosier, Ph.; Scarpaci, J. A.; Tretyak, V. I.; Umatov, V. I.; Velázquez, M.; Zarytskyy, M. M.; Zolotarova, A. (Journal of Instrumentation, 2023)In preparation for the CROSS experiment to search for double-beta (2β) decay of 100Mo, we upgraded a low-background facility at the Canfranc underground laboratory (Spain) by installing a magnetic damping-based detector ... -
Li2100deplMoO4 Scintillating Bolometers for Rare-Event Search Experiments
C. Bandac, Iulian; S. Barabash, Alexander; Bergé, Laurent; A. Borovlev, Yury; Calvo-Mozota, José María; Carniti, Paolo; Chapellier, Maurice; Dafinei, Ioan; A. Danevich, Fedor; Dumoulin, Louis; Ferri, Federico; Giuliani, Andrea; Gotti, Claudio; Gras, Philippe; D. Grigorieva, Veronika; Ianni, Aldo; Khalife, Hawraa; V. Kobychev, Vladislav; I. Konovalov, Sergey; Loaiza, Pia; Madhukuttan, Madhujith; P. Makarov, Evgeny; Marcillac, Pierre de; Marnieros, Stefanos; A. Marrache-Kikuchi, Claire; Martinez, Maria; Nones, Claudia; Olivieri, Emiliano; Ortiz de Solórzano, Alfonso; Pessina, Gianluigi; V. Poda, Denys; Redon, Thierry; Scarpaci, Jean-Antoine; N. Shlegel, Vladimir; I. Tretyak, Volodymyr; I. Umatov, Vladimir; M. Zarytskyy, Mykola; Zolotarova, Anastasiia (Sensors, 2023)We report on the development of scintillating bolometers based on lithium molybdate crystals that contain molybdenum that has depleted into the double-𝛽 active isotope 100 Mo (Li2 100depl MoO4 ). We used two Li2 100depl ...