Twelve-crystal prototype of Li2MoO4 scintillating bolometers for CUPID and CROSS experiments
Autor:
Alfonso, K.
; Armatol, A.
; Augier, C.
; Avignone III, F. T.
; Azzolini, O.
; Balata, M.
; Bandac, I.C.
; Barabash, A. S.
; Bari, G.
; Barresi, A.
; Baudin, D.
; Bellini, F.
; Benato, G.
; Berest, V.
; Beretta, M.
; Bettelli, M.
; Biassoni, M.
; Billard, J.
; Boldrini, V.
; Branca, A.
; Brofferio, C.
; Bucci, C.
; Calvo-Mozota, José María
; Camilleri, J.
; Campani, A.
; Capelli, C.
; Capelli, S.
; Cappelli, L.
; Cardani, L.
; Carniti, P.
; Casali, N.
; Celi, E.
; Chang, C.
; Chiesa, D.
; Clemenza, M.
; Colantoni, I.
; Copello, S.
; Craft, E.
; Cremonesi, O.
; Creswick, R. J.
; Cruciani, A.
; D'Addabbo, A.
; D'Imperio, G.
; Dabagov, S.
; Dafinei, I.
; Danevich, F. A.
; De Jesus, M.
; de Marcillac, P.
; Dell'Oro, S.
; Di Domizio, S.
; Di Lorenzo, S.
; Dixon, T.
; Dompé, V.
; Drobizhev, A.
; Dumoulin, L.
; Fantini, G.
; Faverzani, M.
; Ferri, E.
; Ferri, F.
; Ferroni, F.
; Figueroa-Feliciano, E.
; Foggetta, L.
; Formaggio, J.
; Franceschi, A.
; Fu, C.
; Fu, S.
; Fujikawa, B. K.
; Gallas, A.
; Gascon, J.
; Ghislandi, S.
; Giachero, A.
; Gianvecchio, A.
; Girola, M.
; Gironi, L.
; Giuliani, A.
; Gorla, P.
; Gotti, C.
; Grant, C.
; Gras, P.
; Guillaumon, P. V.
; Gutierrez, T. D.
; Han, K.
; Hansen, E. V.
; Heeger, K. M.
; Helis, D. L.
; Huang, H. Z.
; Ianni, A.
; Imbert, L.
; Johnston, J.
; Juillard, A.
; Karapetrov, G.
; Keppel, G.
; Khalife, H.
; Kobychev, V. V.
; Kolomensky, Yu. G.
; Konovalov, S.I.
; Kowalski, R.
; Langford, T.
; Lefevre, M.
; Liu, R.
; Liu, Y.
; Loaiza, P.
; Ma, L.
; Madhukuttan, M.
; Mancarella, F.
; Marrache-Kikuchi, C. A.
; Marini, L.
; Marnieros, S.
; Martinez, M.
; Maruyama, R. H.
; Ph. Mas
; Mayer, D.
; Mazzitelli, G.
; Mei, Y.
; Milana, S.
; Morganti, S.
; Napolitano, T.
; Nastasi, M.
; Nikkel, J.
; Nisi, S.
; Nones, C.
; Norman, E. B.
; Novosad, V.
; Nutini, I.
; O'Donnell, T.
; Olivieri, E.
; Olmi, M.
; Ouellet, J. L.
; Pagan, S.
; Pagliarone, C.
; Pagnanini, L.
; Pattavina, L.
; Pavan, M.
; Peng, H.
; Pessina, G.
; Pettinacci, V.
; Pira, C.
; Pirro, S.
; Poda, D. V.
; Polischuk, O. G.
; Ponce, I.
; Pozzi, S.
; Previtali, E.
; Puiu, A.
; Quitadamo, S.
; Ressa, A.
; Rizzoli, R.
; Rosenfeld, C.
; Rosier, P.
; Scarpaci, J. A.
; Schmidt, B.
; Sharma, V.
; Shlegel, V. N.
; Singh, V.
; Sisti, M.
; Slocum, P.
; Speller, D.
; Surukuchi, P. T.
; Taffarello, L.
; Tomei, C.
; Torres, J. A.
; Tretyak, V. I.
; Tsymbaliuk, A.
; Velazquez, M.
; Vetter, K. J.
; Wagaarachchi, S. L.
; Wang, G.
; Wang, L.
; Wang, R.
; Welliver, B.
; Wilson, J.
; Wilson, K.
; Winslow, L. A.
; Xue, M.
; Yan, L.
; Yang, J
; Yefremenko, V.
; Umatov, V. I.
; Zarytskyy, M. M.
; Zhang, J.
; Zolotarova, A.
; Zucchelli, S.
Fecha:
2023Palabra clave:
Revista / editorial:
Journal of InstrumentationCitación:
Alfonso, K., Armatol, A., Augier, C., Avignone, F. T., Azzolini, O., Balata, M., ... & Scarpaci, J. A. (2023). Twelve-crystal prototype of Li_2MoO_4 scintillating bolometers for CUPID and CROSS experiments. Journal of Instrumentation, 18(06), P06018.Tipo de Ítem:
articleResumen:
An array of twelve 0.28 kg lithium molybdate (LMO) low-temperature bolometers equipped with 16 bolometric Ge light detectors, aiming at optimization of detector structure for CROSS and CUPID double-beta decay experiments, was constructed and tested in a low-background pulse-tube-based cryostat at the Canfranc underground laboratory in Spain. Performance of the scintillating bolometers was studied depending on the size of phonon NTD-Ge sensors glued to both LMO and Ge absorbers, shape of the Ge light detectors (circular vs. square, from two suppliers), in different light collection conditions (with and without reflector, with aluminum coated LMO crystal surface). The scintillating bolometer array was operated over 8 months in the low-background conditions that allowed to probe a very low, μBq/kg, level of the LMO crystals radioactive contamination by 228Th and 226Ra.
Ficheros en el ítem
Nombre: Twelve-crystal prototype of Li2MoO4 scintillating bolometers for CUPID and CROSS experiments.pdf
Tamaño: 7.302Mb
Formato: application/pdf
Este ítem aparece en la(s) siguiente(s) colección(es)
Estadísticas de uso
Año |
2012 |
2013 |
2014 |
2015 |
2016 |
2017 |
2018 |
2019 |
2020 |
2021 |
2022 |
2023 |
2024 |
Vistas |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
92 |
Descargas |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
19 |
Ítems relacionados
Mostrando ítems relacionados por Título, autor o materia.
-
Development of large-volume 130TeO2 bolometers for the CROSS 2β decay search experiment
Avignone III, F.T.; Barabash, A. S.; Berest, V.; Bergé, L.; Calvo-Mozota, José María; Carniti, P.; Chapellier, M.; Dafinei, I.; Danevich, F.A.; Dumoulin, L.; Ferella, F.; Ferri, F.; Gallas, A.; Giuliani, A.; Gotti, C.; Gras, P.; Ianni, A.; Imbert, L.; Khalife, H.; Kobychev, V. V.; Konovalov, S.I.; Loaiza, P.; de Marcillac, P.; Marnieros, S.; Marrache-Kikuchi, C.A.; Martinez, M.; Nisi, S.; Nones, C.; Olivieri, E.; Ortiz de Solórzano, A.; Peinaud, Y.; Pessina, G.; Poda, D. V.; Rosier, Ph.; Scarpaci, J. A.; Tretyak, V. I.; Umatov, V. I.; Zarytskyy, M. M.; Zolotarova, A. (Journal of Instrumentation, 2024)We report on the development of thermal detectors based on large-size tellurium dioxide crystals (45 × 45 × 45 mm), containing tellurium enriched in 130Te to about 91%, for the CROSS double-beta decay experiment. A powder ... -
A novel mechanical design of a bolometric array for the CROSS double-beta decay experiment
Auguste, D.; Barabash, A.S.; Berest, V.; Bergé, L.; Calvo-Mozota, José María; Carniti, P.; Chapellier, M.; Dafinei, I.; Danevich, F.A.; Dixon, T.; Dumoulin, L.; Ferri, F.; Gallas, A.; Giuliani, A.; Gotti, C.; Gras, P.; Ianni, A.; Imbert, L.; Khalife, H.; Kobychev, V. V.; Konovalov, S. I.; Loaiza, P.; de Marcillac, P.; Marnieros, S.; Marrache-Kikuchi, C. A.; Martinez, M.; Nones, C.; Olivieri, E.; Ortiz de Solórzano, A.; Peinaud, Y.; Pessina, G.; Poda, D. V.; Rosier, Ph.; Scarpaci, J.A.; Tretyak, V. I.; Umatov, V. I.; Zarytskyy, M. M.; Zolotarova, A. (Journal of Instrumentation, 2024)The CROSS experiment will search for neutrinoless double-beta decay using a specific mechanical structure to hold thermal detectors. The design of the structure was tuned to minimize the background contribution, keeping ... -
Test of 116CdWO4 and Li2MoO4 scintillating bolometers in the CROSS underground facility with upgraded detector suspension
Ahmine, A.; Bandac, I. C.; Barabash, A. S.; Berest, V.; Bergé, L.; Calvo-Mozota, José María; Carniti, P.; Chapellier, M.; Dafinei, I.; Danevich, F. A.; Dixon, T.; Dumoulin, L.; Ferri, F.; Giuliani, A.; Gott, C.; Gras, P.; Helis, D. L.; Ianni, A.; Imbert, L.; Khalife, H.; Kobychev, V. V.; Konovalov, S. I.; Loaiza, P.; de Marcillac, P.; Marnieros, S.; Marrache-Kikuchi, C. A.; Martinez, M.; Nones, C.; Olivieri, E.; Ortiz de Solórzano, A.; Peinaud, Y.; Pessina, G.; Poda, D. V.; Redon, Th.; Rosier, Ph.; Scarpaci, J. A.; Tretyak, V. I.; Umatov, V. I.; Velázquez, M.; Zarytskyy, M. M.; Zolotarova, A. (Journal of Instrumentation, 2023)In preparation for the CROSS experiment to search for double-beta (2β) decay of 100Mo, we upgraded a low-background facility at the Canfranc underground laboratory (Spain) by installing a magnetic damping-based detector ...