A novel mechanical design of a bolometric array for the CROSS double-beta decay experiment
Autor:
Auguste, D.
; Barabash, A.S.
; Berest, V.
; Bergé, L.
; Calvo-Mozota, José María
; Carniti, P.
; Chapellier, M.
; Dafinei, I.
; Danevich, F.A.
; Dixon, T.
; Dumoulin, L.
; Ferri, F.
; Gallas, A.
; Giuliani, A.
; Gotti, C.
; Gras, P.
; Ianni, A.
; Imbert, L.
; Khalife, H.
; Kobychev, V. V.
; Konovalov, S. I.
; Loaiza, P.
; de Marcillac, P.
; Marnieros, S.
; Marrache-Kikuchi, C. A.
; Martinez, M.
; Nones, C.
; Olivieri, E.
; Ortiz de Solórzano, A.
; Peinaud, Y.
; Pessina, G.
; Poda, D. V.
; Rosier, Ph.
; Scarpaci, J.A.
; Tretyak, V. I.
; Umatov, V. I.
; Zarytskyy, M. M.
; Zolotarova, A.
Fecha:
2024Palabra clave:
Revista / editorial:
Journal of InstrumentationCitación:
Auguste, D., Barabash, A. S., Berest, V., Bergé, L., Calvo-Mozota, J. M., Carniti, P., ... & Zolotarova, A. (2024). A novel mechanical design of a bolometric array for the CROSS double-beta decay experiment. Journal of Instrumentation, vol. 19. P09014Tipo de Ítem:
Articulo Revista IndexadaResumen:
The CROSS experiment will search for neutrinoless double-beta decay using a specific mechanical structure to hold thermal detectors. The design of the structure was tuned to minimize the background contribution, keeping an optimal detector performance. A single module of the structure holds two scintillating bolometers (with a crystal size of 45 × 45 × 45 mm and a Ge slab facing the crystal's upper side) in the Cu frame, allowing for a modular construction of a large-scale array. Two designs are released: the initialThick version contains around 15% of Cu over the crystal mass (lithium molybdate, LMO), while this ratio is reduced to ∼ 6% in a finer (Slim) design. Both designs were tested extensively at aboveground (IJCLab, France) and underground (LSC, Spain) laboratories. In particular, at LSC we used a pulse-tube-based CROSS facility to operate a 6-crystal array of LMOs enriched/depleted in 100Mo. The tested LMOs show high spectrometric performance in both designs; notably, the measured energy resolution is 5–7 keV FWHM at 2615 keV γs, nearby the Q-value of 100Mo (3034 keV). Due to the absence of a reflective cavity around LMOs, a low scintillation signal is detected by Ge bolometers: ∼ 0.3 keV (150 photons) for 1-MeV γ(β) LMO-event. Despite that, an acceptable separation between α and γ(β) events is achieved with most devices. The highest efficiency is reached with light detectors in the Thick design thanks to a lower baseline noise width (0.05–0.09 keV RMS) when compared to that obtained in the Slim version (0.10–0.35 keV RMS). Given the pivotal role of bolometric photodetectors for particle identification and random coincidences rejection, we will use the structure here described with upgraded light detectors, featuring thermal signal amplification via the Neganov-Trofimov-Luke effect, as also demonstrated in the present work.
Este ítem aparece en la(s) siguiente(s) colección(es)
Estadísticas de uso
Año |
2012 |
2013 |
2014 |
2015 |
2016 |
2017 |
2018 |
2019 |
2020 |
2021 |
2022 |
2023 |
2024 |
2025 |
Vistas |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
15 |
47 |
62 |
Descargas |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
Ítems relacionados
Mostrando ítems relacionados por Título, autor o materia.
-
Development of large-volume 130TeO2 bolometers for the CROSS 2β decay search experiment
Avignone III, F.T.; Barabash, A. S.; Berest, V.; Bergé, L.; Calvo-Mozota, José María; Carniti, P.; Chapellier, M.; Dafinei, I.; Danevich, F.A.; Dumoulin, L.; Ferella, F.; Ferri, F.; Gallas, A.; Giuliani, A.; Gotti, C.; Gras, P.; Ianni, A.; Imbert, L.; Khalife, H.; Kobychev, V. V.; Konovalov, S.I.; Loaiza, P.; de Marcillac, P.; Marnieros, S.; Marrache-Kikuchi, C.A.; Martinez, M.; Nisi, S.; Nones, C.; Olivieri, E.; Ortiz de Solórzano, A.; Peinaud, Y.; Pessina, G.; Poda, D. V.; Rosier, Ph.; Scarpaci, J. A.; Tretyak, V. I.; Umatov, V. I.; Zarytskyy, M. M.; Zolotarova, A. (Journal of Instrumentation, 2024)We report on the development of thermal detectors based on large-size tellurium dioxide crystals (45 × 45 × 45 mm), containing tellurium enriched in 130Te to about 91%, for the CROSS double-beta decay experiment. A powder ... -
Test of 116CdWO4 and Li2MoO4 scintillating bolometers in the CROSS underground facility with upgraded detector suspension
Ahmine, A.; Bandac, I. C.; Barabash, A. S.; Berest, V.; Bergé, L.; Calvo-Mozota, José María; Carniti, P.; Chapellier, M.; Dafinei, I.; Danevich, F. A.; Dixon, T.; Dumoulin, L.; Ferri, F.; Giuliani, A.; Gott, C.; Gras, P.; Helis, D. L.; Ianni, A.; Imbert, L.; Khalife, H.; Kobychev, V. V.; Konovalov, S. I.; Loaiza, P.; de Marcillac, P.; Marnieros, S.; Marrache-Kikuchi, C. A.; Martinez, M.; Nones, C.; Olivieri, E.; Ortiz de Solórzano, A.; Peinaud, Y.; Pessina, G.; Poda, D. V.; Redon, Th.; Rosier, Ph.; Scarpaci, J. A.; Tretyak, V. I.; Umatov, V. I.; Velázquez, M.; Zarytskyy, M. M.; Zolotarova, A. (Journal of Instrumentation, 2023)In preparation for the CROSS experiment to search for double-beta (2β) decay of 100Mo, we upgraded a low-background facility at the Canfranc underground laboratory (Spain) by installing a magnetic damping-based detector ... -
Twelve-crystal prototype of Li2MoO4 scintillating bolometers for CUPID and CROSS experiments
Alfonso, K.; Armatol, A.; Augier, C.; Avignone III, F. T.; Azzolini, O.; Balata, M.; Bandac, I.C.; Barabash, A. S.; Bari, G.; Barresi, A.; Baudin, D.; Bellini, F.; Benato, G.; Berest, V.; Beretta, M.; Bettelli, M.; Biassoni, M.; Billard, J.; Boldrini, V.; Branca, A.; Brofferio, C.; Bucci, C.; Calvo-Mozota, José María; Camilleri, J.; Campani, A.; Capelli, C.; Capelli, S.; Cappelli, L.; Cardani, L.; Carniti, P.; Casali, N.; Celi, E.; Chang, C.; Chiesa, D.; Clemenza, M.; Colantoni, I.; Copello, S.; Craft, E.; Cremonesi, O.; Creswick, R. J.; Cruciani, A.; D'Addabbo, A.; D'Imperio, G.; Dabagov, S.; Dafinei, I.; Danevich, F. A.; De Jesus, M.; de Marcillac, P.; Dell'Oro, S.; Di Domizio, S.; Di Lorenzo, S.; Dixon, T.; Dompé, V.; Drobizhev, A.; Dumoulin, L.; Fantini, G.; Faverzani, M.; Ferri, E.; Ferri, F.; Ferroni, F.; Figueroa-Feliciano, E.; Foggetta, L.; Formaggio, J.; Franceschi, A.; Fu, C.; Fu, S.; Fujikawa, B. K.; Gallas, A.; Gascon, J.; Ghislandi, S.; Giachero, A.; Gianvecchio, A.; Girola, M.; Gironi, L.; Giuliani, A.; Gorla, P.; Gotti, C.; Grant, C.; Gras, P.; Guillaumon, P. V.; Gutierrez, T. D.; Han, K.; Hansen, E. V.; Heeger, K. M.; Helis, D. L.; Huang, H. Z.; Ianni, A.; Imbert, L.; Johnston, J.; Juillard, A.; Karapetrov, G.; Keppel, G.; Khalife, H.; Kobychev, V. V.; Kolomensky, Yu. G.; Konovalov, S.I.; Kowalski, R.; Langford, T.; Lefevre, M.; Liu, R.; Liu, Y.; Loaiza, P.; Ma, L.; Madhukuttan, M.; Mancarella, F.; Marrache-Kikuchi, C. A.; Marini, L.; Marnieros, S.; Martinez, M.; Maruyama, R. H.; Ph. Mas; Mayer, D.; Mazzitelli, G.; Mei, Y.; Milana, S.; Morganti, S.; Napolitano, T.; Nastasi, M.; Nikkel, J.; Nisi, S.; Nones, C.; Norman, E. B.; Novosad, V.; Nutini, I.; O'Donnell, T.; Olivieri, E.; Olmi, M.; Ouellet, J. L.; Pagan, S.; Pagliarone, C.; Pagnanini, L.; Pattavina, L.; Pavan, M.; Peng, H.; Pessina, G.; Pettinacci, V.; Pira, C.; Pirro, S.; Poda, D. V.; Polischuk, O. G.; Ponce, I.; Pozzi, S.; Previtali, E.; Puiu, A.; Quitadamo, S.; Ressa, A.; Rizzoli, R.; Rosenfeld, C.; Rosier, P.; Scarpaci, J. A.; Schmidt, B.; Sharma, V.; Shlegel, V. N.; Singh, V.; Sisti, M.; Slocum, P.; Speller, D.; Surukuchi, P. T.; Taffarello, L.; Tomei, C.; Torres, J. A.; Tretyak, V. I.; Tsymbaliuk, A.; Velazquez, M.; Vetter, K. J.; Wagaarachchi, S. L.; Wang, G.; Wang, L.; Wang, R.; Welliver, B.; Wilson, J.; Wilson, K.; Winslow, L. A.; Xue, M.; Yan, L.; Yang, J; Yefremenko, V.; Umatov, V. I.; Zarytskyy, M. M.; Zhang, J.; Zolotarova, A.; Zucchelli, S. (Journal of Instrumentation, 2023)An array of twelve 0.28 kg lithium molybdate (LMO) low-temperature bolometers equipped with 16 bolometric Ge light detectors, aiming at optimization of detector structure for CROSS and CUPID double-beta decay experiments, ...