    Cyber-Physical System Architecture for Minimizing the Possibility of Producing Bad Products in a Manufacturing System

    Autor: 
    Cobos Guzman, Salvador
    ;
    Cima Cabal, María Dolores
    ;
    Machio Regidor, Francisco
    ;
    Alonso Virgos, Lucia
    Fecha: 
    2019
    Palabra clave: 
    cyber-physical systems; industry 4.0; lean manufacturing; agile production; increase of quality
    Revista / editorial: 
    IntechOpen
    Citación: 
    Guzman, S. C., Cabal, M. D. C., Regidor, F. M., & Virgos, L. A. (2019). Cyber-physical system architecture for minimizing the possibility of producing bad products in a manufacturing system. In Industry 4.0-Impact on Intelligent Logistics and Manufacturing. IntechOpen.
    Tipo de Ítem: 
    bookPart
    URI: 
    https://reunir.unir.net/handle/123456789/17703
    DOI: 
    https://doi.org/10.5772/intechopen.88461
    Dirección web: 
    https://www.intechopen.com/chapters/69091#
    Open Access
    Resumen:
    Abstract The new industry 4.0 requires the implementation of several cyber-physical systems to increase the level of productivity in a manufacturing system. This chapter proposes an architecture of a generic manufacturing system that requires the use of techniques of agile production, lean manufacturing, and statistical approaches. The combination of the previous techniques will be implemented in the architecture proposed for minimizing the possibility of producing bad products. Thus, the cyber-physical system architecture proposed will optimize the overall system thanks to the implementation of intelligent modules and control strategies. Moreover, 10 proposed actions will be described in detail. These actions can be implemented in cyber-physical systems that take into account five levels.
    Mostrar el registro completo del ítem
    Ficheros en el ítem
    icon
    Nombre: Cyber-Physical System Architecture for Minimizing.pdf
    Tamaño: 1.752Mb
    Formato: application/pdf
    Ver/Abrir
    Este ítem aparece en la(s) siguiente(s) colección(es)
    • Otras Publicaciones: artículos, libros...

    Estadísticas de uso

    Año
    2012
    2013
    2014
    2015
    2016
    2017
    2018
    2019
    2020
    2021
    2022
    2023
    2024
    2025
    Vistas
    0
    0
    0
    0
    0
    0
    0
    0
    0
    0
    0
    0
    0
    60
    Descargas
    0
    0
    0
    0
    0
    0
    0
    0
    0
    0
    0
    0
    0
    43

    Ítems relacionados

    Mostrando ítems relacionados por Título, autor o materia.

    • Magnetic Nanoclusters Increase the Sensitivity of Lateral Flow Immunoassays for Protein Detection: Application to Pneumolysin as a Biomarker for Streptococcus pneumoniae 

      Salvador, Maria; Marques-Fernandez, Jose Luis; Bunge, Alexander; Martinez-Garcia, Jose Carlos; Turcu, Rodica; Peddis, Davide; García-Suárez, María del Mar ; Cima-Cabal, María Dolores ; Rivas, Montserrat (Nanomaterials, 06/2022)
      Lateral flow immunoassays for detecting biomarkers in body fluids are simple, quick, inexpensive point-of-care tests widely used in disease surveillance, such as during the coronavirus disease 2019 (COVID-19) pandemic. ...
    • Developing Diagnostic and Therapeutic Approaches to Bacterial Infections for a New Era: Implications of Globalization 

      Fernández, Lucía; Cima-Cabal, María Dolores ; Catarina Duarte, Ana; Rodríguez, Ana; García, Pilar; García-Suárez, María del Mar (Antibiotics-Basel, 12/2020)
      In just a few months, the current coronavirus pandemic has exposed the need for a more global approach to human health. Indeed, the quick spread of infectious diseases and their unpredictable consequences, in terms of human ...
    • Gram-positive pneumonia: Possibilities offered by phage therapy 

      Fernández, Lucía; Cima-Cabal, María Dolores ; Catarina Duarte, Ana; Rodríguez, Ana; García-Suárez, María del Mar ; García, Pilar (MDPI, 2021)
      Pneumonia is an acute pulmonary infection whose high hospitalization and mortality rates can, on occasion, bring healthcare systems to the brink of collapse. Both viral and bacterial pneumonia are uncovering many gaps in ...

    Mi cuenta

    AccederRegistrar

    ¿necesitas ayuda?

    Manual de UsuarioContacto: reunir@unir.net

    Listar

    todo Re-UnirComunidades y coleccionesPor fecha de publicaciónAutoresTítulosPalabras claveTipo documentoTipo de accesoEsta colecciónPor fecha de publicaciónAutoresTítulosPalabras claveTipo documentoTipo de acceso






    Aviso Legal Política de Privacidad Política de Cookies Cláusulas legales RGPD
    © UNIR - Universidad Internacional de La Rioja
     
    Aviso Legal Política de Privacidad Política de Cookies Cláusulas legales RGPD
    © UNIR - Universidad Internacional de La Rioja